Browse all practice questions for the Electrical Lineworker Training – Grounding 1 (GR1) and Transformers 1 (TR1) Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Electrical Lineworker Training – Grounding 1 (GR1) and Transformers 1 (TR1) Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is magnetizing inrush current?
  • Which statement best describes the primary function of personal protective grounding?
  • Why must a tap changer be operated only as allowed by its design and procedure?
  • What term describes the voltage difference between two conducting objects?
  • What is the minimum size of grounding conductors used for transmission?
  • Which pair of system characteristics is associated with ferroresonance?
  • Why is correct polarity important when connecting single-phase transformers in parallel?
  • Which transformer winding is connected to the load?
  • Where will fault currents be higher?
  • What do substations with high fault current require two sets of?
  • Which of the following best describes the effect of having a bank of transformers rated additively when connected in parallel?
  • In CSP transformer terminology, CSP stands for?
  • A worker treats the transformer neutral and enclosure ground as interchangeable. What is the key problem with that assumption?
  • What is the usual safe sequence for removing a temporary protective ground set?
  • Which statement best distinguishes a transformer neutral from its equipment enclosure ground?
  • Why is the transformer core laminated?
  • What is the primary side of a transformer known as?
  • Which statement correctly describes the standard relationship of primary and secondary designation for windings?
  • What does transformer backfeed mean?
  • What does KVA stand for?
  • Does a lineworker have to install a cluster bar to create an equipotential zone?
  • For an ideal transformer, how does current relate to the winding turns ratio?
  • In a pad-mount transformer, what is the purpose of the bayonet fuse?
  • Which hazard can remain even when a line is intentionally deenergized and connected to earth?
  • Which information is needed to select an adequate temporary grounding cable rating?
  • What is any difference in electrical potential between two conducting objects?
  • A transformer is energized, and a brief large current flows while magnetic flux is being established. What is this current called?
  • Capacitance is best described as which property?
  • What does the term kVA stand for?
  • What is the most effective way to protect a lineworker if the line or equipment becomes energized?
  • What is the term for the ground path created when you lean against an object or vehicle and touch another object?
  • Which statement about a temporary protective ground is correct?
  • The winding that delivers power to the load is called the what?
  • A balanced delta-connected system has a phase voltage of 240 volts. What is its line voltage?
  • What does a step-up transformer do?
  • What are the two main objectives of grounding?
  • In a balanced three-phase delta connection, how does line voltage compare with phase voltage?
  • Which statement about protective grounding is true?
  • A voltage difference exists between two points on the ground separated by a person’s stride. What is this hazard called?
  • What is the purpose of a ground cluster or bonding point in a work zone?
  • In its simplest form, how many components does a transformer consist of?
  • What does a transformer’s kVA rating specify?
  • An overhead distribution transformer that needs an external protective device for protection is called what?
  • What does changing a transformer tap do?
  • Two transformers have different frequency ratings. What should be concluded before connecting them in parallel?
  • For an additive connection, which sequence lists the secondary winding terminals?
  • Which description best defines an equipotential work zone?
  • Why should a lineworker test equipment for voltage even after it has been deenergized?
  • What is the primary purpose of bonding conductive objects within a work zone?
  • A grounding connection has poor contact during a fault. Which hazard is most directly increased?
  • Which set of conditions includes possible sources that should be considered before grounding equipment?
  • Pad-mount transformers are most commonly used in which setting?
  • If deenergized equipment becomes energized unexpectedly, what role do temporary protective grounds serve?
  • Do transformers have many moving parts?
  • Which statement correctly identifies the additive connection mapping for transformer windings?
  • Which description best identifies ferroresonance?
  • Is proper application and installation of personal protective grounds critical for lineworkers to understand?
  • Which set of system needs should be considered when selecting or replacing a transformer?
  • What is the secondary side of a transformer known as?
  • Fault current is defined as the amount of what a system can deliver to a fault or short circuit?
  • What is the primary safety purpose of bonding a transformer’s conductive enclosure?
  • Why is ferroresonance a concern in a distribution system?
  • In a pad-mounted single-phase transformer, the primary side is on the left and the secondary on the right. What are the primary bushings designated as?
  • A transformer is best described as which of the following?
  • What may happen if a transformer winding is connected incorrectly?
  • Does an increase in voltage cause a corresponding increase in current?
  • Which winding arrangement forms a closed loop and has no inherent neutral point?
  • Approximately what percent of the human body is water?
  • What is the usual safe sequence for installing a temporary protective ground set?
  • A worker finds corrosion and a loose connection on a grounding clamp before use. What is the main safety concern?
  • What is the primary electrical benefit of applying temporary protective grounds to deenergized line equipment?
  • Why should temporary protective grounds be placed as close as practicable to the work location?
  • What is the efficiency range of most modern transformers?
  • How many volt-amperes are represented by a 100 KVA transformer?
  • In power distribution, which option best describes the primary purpose of transformers?
  • When beginning to install a temporary protective ground set, which connection is ordinarily made first?
  • An ideal transformer has a primary-to-secondary turns ratio of 1:4. If the primary current is 8 amperes, what is the secondary current?
  • Why does a nearby energized parallel line require attention when grounding a deenergized line?
  • An ideal transformer has 100 turns on its primary winding and 50 turns on its secondary winding. If the primary voltage is 120 volts, what is the secondary voltage?
  • A line has been deenergized for work. Which condition could still create hazardous voltage on it?
  • What is the best basis for replacing a transformer with another unit?
  • True or False: Additive rating applies to 200 KVA and smaller transformers only if the primary rating is 8,660 volts or below.
  • Which situation describes touch potential rather than step potential?
  • What information do polarity markings on transformer terminals provide?
  • Why can a transformer’s secondary voltage decrease when it supplies a heavier load?
  • Which transformer winding is connected to the source?
  • Which commercial metal has the highest conductivity and excellent resistance to oxidation and corrosion?
  • Is polarity set during manufacturing and unable to be changed in the field?
  • In a step-down transformer, which coil has more turns?
  • Ferroresonance in a distribution system involves resonance between which elements?
  • When a procedure requires grounding on both sides of a work zone, what is the main purpose?
  • In a step-up transformer, which coil has more turns?
  • A worker disconnects the primary supply but finds voltage at the transformer’s primary-side terminals. Which condition could explain this?
  • A replacement transformer must be suitable for the system’s operating voltage. What should guide the selection?
  • Distribution transformers are rated in size by which unit?
  • Can radio, television, and microwave towers be a source of induced voltage?
  • What is the preferred method of protecting lineworkers while working on de-energized lines and equipment?
  • A generator back feed is an example of what?
  • Why should a transformer’s secondary circuit be treated as energized even when its primary is disconnected?
  • The primary bushings of an overhead distribution transformer are labeled H1 and H2. Which side are they on when facing the transformer?
  • In an ideal transformer, which winding has proportionally lower current?
  • The secondary winding terminals are designated as which of the following?
  • Which statement about additive rating is true?
  • Which OSHA standard gives the lineworker a basis for grounding?
  • What is the difference in potential that can occur between a worker's feet?
  • Which description applies to a transformer neutral?
  • Before connecting transformer windings, what should be verified to reduce the risk of damaging circulating currents?
  • What indicates the direction of current flow in a transformer?
  • The winding that is connected to the source is called the what?
  • What cannot provide a means of protection from electrical hazards?
  • What substance is commonly used to cool and insulate a transformer?
  • What is the most common type of underground transformer in the distribution system?
  • Why may an earth connection alone be insufficient to protect workers?
  • For a given transformer, what is the general effect of lower impedance on short-circuit current?
  • Which component relieves internal pressure in a transformer?
  • A worker could be exposed to current passing through the legs because the ground has different voltages at the worker’s two feet. Which hazard is involved?
  • Is a hot-line clamp suitable for grounding during a short duration?
  • Personal protective grounding is designed to direct electricity safely away from whom?
  • A transformer has a turns ratio of 30:1. If the primary is 7200 volts, what is the approximate secondary voltage?
  • What is the function of a transformer in an alternating-current system?
  • Which term is used to refer to the side where power is delivered to the load?
  • Which condition may result from ferroresonance in a distribution system?
  • A worker is checking the purpose of the equipment enclosure ground. Which function is appropriate?
  • Which statement about aluminum conductors, compared to copper, is true?
  • In a balanced three-phase wye system, how does line voltage compare with phase voltage?
  • What can store electricity and retain a charge after being de-energized?
  • When three identical transformers are connected in a closed bank, the bank’s total rating is determined by which of the following?
  • Fault current availability can affect grounding size and quantity.
  • A worker contacts a conductive object while standing on the ground. The voltage difference between the object and the ground beneath the worker is called what?
  • Why should workers use an employer-approved grounding procedure instead of improvising an arrangement?
  • How many accepted methods of protection are there for a lineworker to keep from becoming energized?
  • Transformers 200 KVA and smaller with a primary rating of what voltage and below will be rated additive?
  • What can occur when parallel transformers have significantly different impedances?
  • What is encountered from existing energized lines adjacent to the work site?
  • What is a potential consequence of excessive resistance in a temporary grounding set?
  • How does an equipotential work zone reduce the risk of electric shock?
  • An ideal transformer has four times as many turns on its secondary winding as on its primary winding. How does the secondary voltage compare with the primary voltage?
  • Which standard should be consulted for grounding requirements in electrical work on power distribution?
  • What device is used to relieve internal pressure in a transformer?
  • Which statement is true regarding preventing current from flowing through a lineworker?
  • Which phenomenon occurs when energy is unintentionally supplied to a circuit due to back feeding from a source?
  • The transformer core is typically laminated from which material?
  • What is the minimum size of grounds used for distribution?
  • What is an open-delta transformer bank?
  • For an ideal transformer, which relationship describes primary and secondary voltage?
  • Can a hot-line clamp be used as a ground clamp for a short duration?
  • How much amperage does it take to affect the human heart?
  • Before two transformers are operated in parallel, which set of characteristics should be compatible?
  • Does the size of the neutral affect the amount of resistance that limits current flow?
  • In power distribution, which option best describes the primary purpose of transformers?
  • H1 and H2 labeling refers to which winding?
  • Does the size of the neutral affect the amount of resistance that limits current flow?
  • Which statement describes the function of a step-down transformer?
  • Which transformer feature is intended to adjust the voltage ratio by changing the effective number of winding turns?
  • Why should grounding clamps and connection points be clean and secure?
  • Which statement best distinguishes a temporary protective ground from a permanent system ground?
  • Which item is commonly listed on a transformer nameplate?
  • A de-energized line may be exposed to voltage induced by nearby energized conductors. What should workers do before applying grounds?
  • Which grounding approach ensures all exposed conductive surfaces are at the same potential?
  • How does a low-impedance grounding path contribute to worker protection during a fault?
  • How much current does a common light bulb draw?
  • Which item is one of the requirements that a correctly selected transformer should suit?
  • When system design calls for grounding a transformer neutral, what is the main purpose?
  • On average, aluminum conductors are how much cheaper than copper conductors?
  • What are the connection points from the windings inside the transformer to the conductors outside called?
  • A grounding set is selected based only on the nominal line voltage. What important selection information has been overlooked?
  • Why may temporary protective grounds be needed on both sides of a work location?
  • What should a grounding plan establish before work begins?
  • True or False: The safety objective of grounding is to limit both the current that can flow through a worker and the duration of that flow.
  • What material is the transformer core typically made from?
  • The minimum size of grounding conductors used in distribution is which gauge?
  • What is the main benefit of bonding a worker's conductive work area and associated equipment to a common point?
  • Do transformers operate on alternating current or direct current?
  • Why should workers use a transformer’s ratings and approved procedures when selecting or replacing a unit?
  • Which winding is typically connected to the load?
  • Which statement best describes the primary advantage of copper conductors in distribution systems?
  • Why can magnetizing inrush cause a protective device to operate during transformer energization?
  • Three transformers rated at 15 KVA each are connected in a closed bank. What is the total KVA rating?
  • What is the only way to completely prevent current from flowing through a lineworker's body while contacting an energized line?
  • A three-phase motor rotates in the wrong direction after a transformer bank is connected. Which connection check is especially relevant?
  • What is the neutral connection on a transformer called?
  • Can transformers of different KVA sizes be used to supply a large 120/240-volt single-phase load along with smaller three-phase loads?
  • What is a key hazard of paralleling transformer windings with mismatched voltages?
  • Are fault current levels the same for each circuit?
  • What can fault current availability affect and possibly determine?
  • Which feature is characteristic of a wye winding connection?
  • Why is phase sequence checked when connecting a three-phase transformer bank?
  • What is the purpose of bonding conductive objects that a worker may contact within a protected work area?
  • A two-transformer open-delta bank uses comparable transformer units under balanced conditions. Approximately what fraction of the capacity of a three-transformer closed-delta bank can it deliver?
  • In a balanced wye system, a phase voltage is 120 V. What is the approximate line voltage?
  • What is the most important element in any work practice or process when working on an electrical high-voltage system?
  • Fault currents tend to be highest in proximity to which part of the system?
  • What is the turns ratio of a transformer with voltages 7200/12470 and 120/240?
  • What is an electrical device that changes one value of AC voltage into another value of AC voltage?
  • Underground transformers typically come in how many configurations?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy